The network is maintained by the RBG Network and System Group.
We have five different VLANs/Networks.
VLAN-Name: | il11 | il11_2 | il11_3 | il11_4 | il11_5 | il11_6 | il11_8 |
---|---|---|---|---|---|---|---|
VLAN-ID: | vlan_83 | vlan_132 | vlan_133 | vlan_235 | vlan_240 | vlan_241 | vlan_253 |
Note: | chair | server mgmt (iDrac) | server intern | wlan (free) | server mwn | testbed back | testbed front |
Netzwerk: | 131.159.24.0/23 | 10.0.0.0/8 | 10.200.112.0/20 | 172.24.21.192/27 | 172.24.24.0/23 | 10.200.104.0/21 | 10.200.96.0/21 |
Gateway: | 131.159.25.254 | 10.0.0.1 | 10.200.127.254 | 172.24.21.219(DHCP:..21.220) | 172.24.25.254 | 10.200.111.254 | 10.200.103.254 |
HostMin: | 131.159.24.1 | 10.0.0.1 | 10.200.112.1 | 172.24.21.193 | 172.24.24.1 | 10.200.104.1 | 10.200.96.1 |
HostMax: | 131.159.25.253 | 10.255.255.254 | 10.200.127.249 | 172.24.21.222 | 172.24.25.253 | 10.200.111.249 | 10.200.103.254 |
Broadcast: | 131.159.25.255 | 10.255.255.255 | 10.200.127.255 | 172.24.21.223 | 172.24.25.255 | 10.200.111.255 | 10.200.103.255 |
Netzmaske: | 255.255.254.0 = 23 | 255.0.0.0 = 8 | 255.255.240.0 = 20 | 55.255.255.224 = 27 | 255.255.254.0 = 23 | 255.255.248.0 = 21 | 255.255.248.0 = 21 |
Hosts/Netz: | 510 | 4094 | 4094 | 30 | 510 | 2046 | 2046 |
The addresses from this range can be directly assigned to the device. For some networks an internal RBG DHCP server can be used to automatically provide addresses.
Chair IPs (il11)
Chair addresses can be managed through the RBG Webapp. The MAC address needs to be whitelisted for the DHCP server. In this way each IP address is coupled with a user (MAC address).
The VPN access is granted by an entry in a LDAP group (vpnil11). Only employees should be added to the ldap group!! The Ldap group is managed through the RBGWebapp.
To give students access to chair services/vms/servers the firewall should be opened to allow connections from the LRZ VPN range to this particular service/vm.
The chair firewall is managed by the network group. An E-Mail has to be sent with the rule that needs to be added. Each network has its own firewall (→ ac_il11, ac_il11_2, etc.). Usually the chair firewall is meant. The specific rules and setup can be found under firewall
E.g. vmott4 (IP) ← Port 443 ← alle Netze, net01 (IP) ← Port 22 ← LRZ VPN, etc.
The network group does not like external access points. They interfere with the existing wifi infrastructure and the situation gets worse. We have one hidden chair network that is accessible with only a password from all access points that also broadcast the eduroam network in the FMI building. Two ports of the meeting room switch are also connected to this network. Visitors can plug in a Ethernet cable and should get immediate internet connection.
VLAN: | il11_4 |
---|
look at the table above for the rest of the information
This network has a gateway to control access to our chair network, this gateway is managed by us and can be accessed on vmott3. More information on how the gateway is set up can be found in the sections below.
This is the gateway controlling the access from the chair WIFI (il11_4) to the rest of the chair network. This gateway is vmott3.
Setup
net.ipv4.ip_forward=1
in /etc/sysctl.conf
/etc/network/interfaces
auto ens192 auto ens192 iface ens192 inet dhcp
ens160
= chair network, ens192
= il11 network#nat everything except traffic between chair and il11 (both ways) iptables -t nat -A POSTROUTING ! -s 131.159.24.0/23 ! -d 131.159.24.0/23 -j SNAT --to-source 131.159.24.141 #allow traffic only from chair network to gateway (INPUT) iptables -A INPUT -i ens160 -m state --state RELATED,ESTABLISHED -j ACCEPT iptables -A INPUT -i ens160 -s 131.159.24.0/23 -j ACCEPT #allow special traffic to be forwarded (FORWARD) iptables -A FORWARD -m state --state RELATED,ESTABLISHED -j ACCEPT # allow influxDB and MonoDB from il11 to testbed02 (FORWARD) iptables -A FORWARD -i ens192 -o ens160 -p tcp -s 172.24.21.192/27 -d 131.159.24.150 --sport 1024:65535 --dport 8086 -j ACCEPT iptables -A FORWARD -i ens192 -o ens160 -p tcp -s 172.24.21.192/27 -d 131.159.24.150 --sport 1024:65535 --dport 27017 -j ACCEPT # allow influx DB and Node.js from testbed02 to il11 iptables -A FORWARD -i ens160 -o ens192 -p tcp -s 131.159.24.150 -d 172.24.21.192/27 --dport 8086 -j ACCEPT iptables -A FORWARD -i ens160 -o ens192 -p tcp -s 131.159.24.150 -d 172.24.21.192/27 --dport 8080 -j ACCEPT # allow MYSQL from vmott1 iptables -A FORWARD -i ens160 -o ens192 -p tcp -s 131.159.24.38 -d 172.24.21.192/27 --dport 3306 -j ACCEPT #set default policy to drop any traffic forwarded or addressed to the gateway machine iptables -P INPUT DROP iptables -P FORWARD DROP
iptables-save > /etc/firewall.conf
add new file /etc/network/if-up.d/iptables
with following content
#!/bin/sh iptables-restore /etc/firewall.conf
make the file executable
chmod +x /etc/network/if-up.d/iptables
iptables-save > /etc/firewall.conf
Servers are wired as instructed by the chair admin at installation time by the RBG-network group. There are usually multiple uplinks on one server:
UPDATE:
The server room network consists of our own infrastructure and uplinks to the RBG network. Most of the hardware is wired internally with fibreglass (10G/40G). Most of the servers have a direct link to the RBG switches (chair-network + internet) with a normal 1Gb Ethernet cable. Each server should have at least two interfaces. One interface for the iDrac network (cm-mgmt, Server Management) and one for the chair-network/server-network.
Most of our network cards and all the switches have SFP+ Ports (10G) and QSFP (40G) Ports. The Port itself can be equipped with any kind of transceiver. The transceiver converts the electrical signal to the cable and on the other side back to the electrical signal. So the same port can be used for copper and also fiberglass. For each connection between server and switch two transceivers are needed and one cable in between.
SFP+ Ports are for bandwidths up to 10G. If purchasing transceiver they should be chosen by compatibility between transceiver and server/switch. For the Intel X520 Network cards the E10GSFPSR Transceiver is compatible. With this number also OEM products can be chosen. They don't need to be directly from the original vendor (e.g. Intel) but Vendor certified (OEM) guarantees compatibility. We need SR transceiver for Short Lengths, there are also LR Transceiver which are used for lengths starting from a couple of kilometers. For the exact model and number you can alway ask the RBG-Network group mailto:rbg-noc@in.tum.de.
There are cables that already provide two transceiver and one cable in the middle. For example the cables from the emu03-emu14 servers to the Dell Switch are all Dell Networking Direct Attach Copper Cables with 3m. They are basically transceiver and cable combined.